{"product_id":"kdjb-802y-microcomputer-secondary-injection-relay-protection-tester","title":"KDJB-802Y Microcomputer Secondary Injection Relay Protection Tester | DSP Controlled 3 Phase Test System","description":"\u003cdiv style=\"font-family: Arial,Helvetica,sans-serif; line-height: 1.7; color: #222;\"\u003e\n\u003csection style=\"padding: 28px 22px; border-radius: 16px; background: linear-gradient(135deg,#eef6ff,#ffffff); margin-bottom: 25px;\"\u003e\n\u003ch1 style=\"color: #123b63; margin-top: 0;\"\u003e⚡ KDJB-802Y Microcomputer Secondary Injection Relay Protection Tester\u003c\/h1\u003e\n\u003cp style=\"font-size: 18px;\"\u003e\u003cstrong\u003eDSP Control • Secondary Injection Testing • AC\/DC Output • 3-Phase Testing • Substation Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 18px;\"\u003e\u003cstrong\u003eKDJB-802Y — \u003cem\u003eRelay Protection \/ Secondary Injection Tester\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 18px;\"\u003e\u003cstrong\u003e\u003cem\u003eUTE 403 — CT\/PT Analyzer\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eKDJB-802Y\u003c\/strong\u003e is a professional microcomputer-controlled relay protection testing system designed for electrical protection testing, secondary injection testing, commissioning, maintenance and laboratory applications.\u003c\/p\u003e\n\u003cp\u003eWith controlled AC and DC current and voltage outputs, adjustable frequency capability and DSP-based control, the system provides engineers and technicians with a practical platform for testing protection relays and associated secondary circuits.\u003c\/p\u003e\n\u003cdiv style=\"padding: 15px; background: #fff; border-left: 5px solid #1976d2; border-radius: 8px;\"\u003e\n\u003cstrong\u003eProfessional Testing Equipment:\u003c\/strong\u003e Intended for qualified electrical engineers, protection technicians, commissioning personnel, testing laboratories and trained operators.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/Hdd149c6dcc2f40e58d378635b039021bl.jpg?v=1788589019\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e🚀 Key Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(220px,1fr)); gap: 14px;\"\u003e\n\u003cdiv style=\"padding: 18px; background: #f5faff; border-radius: 12px;\"\u003e\n\u003ch3\u003e🧠 DSP Control\u003c\/h3\u003e\n\u003cp\u003eMicrocomputer and DSP-based control architecture for controlled electrical test outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 18px; background: #f7fff7; border-radius: 12px;\"\u003e\n\u003ch3\u003e⚡ AC Current Output\u003c\/h3\u003e\n\u003cp\u003eUp to 40 A per phase with up to 120 A three-phase parallel current output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 18px; background: #fffaf3; border-radius: 12px;\"\u003e\n\u003ch3\u003e🔋 DC Testing\u003c\/h3\u003e\n\u003cp\u003eDC current and voltage output capability for applicable protection-testing procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 18px; background: #faf5ff; border-radius: 12px;\"\u003e\n\u003ch3\u003e🎯 High Accuracy\u003c\/h3\u003e\n\u003cp\u003eApproximately 0.2 accuracy class according to the supplied specification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/Hfac6d115d16447fcb9067b46f9f3a4f24.jpg?v=1788589019\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/H24890d3ef7774b38b37fbca21aefa742T.jpg?v=1788589019\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/Hd5bb66b7c5af422fa78a4a1f776d3eef8.jpg?v=1788589018\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/H25733df22d7f4c66b1717ab87f8301daa.jpg?v=1788589018\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/Hdd149c6dcc2f40e58d378635b039021bl.jpg?v=1788589019\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #123b63; color: white;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003eKDJB-802Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003eMicrocomputer Relay Protection Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eControl\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003eMicrocomputer \/ DSP Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003eApproximately 0.2 Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eAC Phase Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0-40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eAC 3-Phase Parallel Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0-120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0 to ±10 A per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eDC 3-Phase Parallel Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0 to ±30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eAC Phase Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0-120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eAC Line Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0-240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eDC Phase Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0 to ±160 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eDC Line Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e0 to ±320 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e20-1000 Hz Fundamental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eMaximum DC Output Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #ddd;\"\u003eApprox. 420 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eAC 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection style=\"padding: 25px; background: #f8fafc; border-radius: 16px; margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e🔬 Secondary Injection Testing\u003c\/h2\u003e\n\u003cp\u003eSecondary injection testing is used to apply controlled electrical quantities to protection-relay circuits in order to verify relay response and protection-system behaviour.\u003c\/p\u003e\n\u003cp\u003eThe KDJB-802Y provides controlled AC\/DC current and voltage outputs suitable for applicable protection-relay testing procedures.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e⚡ AC current injection\u003c\/li\u003e\n\u003cli\u003e⚡ DC current testing\u003c\/li\u003e\n\u003cli\u003e🔌 AC voltage testing\u003c\/li\u003e\n\u003cli\u003e🔋 DC voltage testing\u003c\/li\u003e\n\u003cli\u003e📈 Frequency adjustment\u003c\/li\u003e\n\u003cli\u003e🎯 Protection relay verification\u003c\/li\u003e\n\u003cli\u003e🏭 Commissioning and maintenance applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/H311f2500963d4dffa8899f344eec6a44o.avif?v=1788589208\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/Hba829d0c1048444dbbbdb5f1fcf6334cJ_5c88e6f4-5143-4fee-bac1-314f09ee524c.avif?v=1788589216\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e🏭 Application Areas\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(220px,1fr)); gap: 12px;\"\u003e\n\u003cdiv style=\"padding: 16px; border: 1px solid #ddd; border-radius: 10px;\"\u003e🏢 \u003cstrong\u003ePower Utilities\u003c\/strong\u003e\n\u003cp\u003eProtection-system testing and maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border: 1px solid #ddd; border-radius: 10px;\"\u003e⚡ \u003cstrong\u003eSubstations\u003c\/strong\u003e\n\u003cp\u003eRelay commissioning and maintenance applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border: 1px solid #ddd; border-radius: 10px;\"\u003e🔧 \u003cstrong\u003eElectrical Contractors\u003c\/strong\u003e\n\u003cp\u003eTesting during electrical commissioning projects.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border: 1px solid #ddd; border-radius: 10px;\"\u003e🔬 \u003cstrong\u003eTesting Laboratories\u003c\/strong\u003e\n\u003cp\u003eElectrical protection testing and technical training.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border: 1px solid #ddd; border-radius: 10px;\"\u003e🏭 \u003cstrong\u003eIndustrial Plants\u003c\/strong\u003e\n\u003cp\u003eElectrical protection maintenance applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border: 1px solid #ddd; border-radius: 10px;\"\u003e🎓 \u003cstrong\u003eEngineering Institutions\u003c\/strong\u003e\n\u003cp\u003eSuitable for advanced electrical testing laboratories subject to curriculum requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection style=\"padding: 25px; background: linear-gradient(135deg,#111827,#1f3b5b); color: white; border-radius: 16px; margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: white;\"\u003e📊 Output Capability at a Glance\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: white;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003e\u003cstrong\u003eAC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003eUp to 40 A \/ phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003e\u003cstrong\u003e3-Phase Parallel AC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003eUp to 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003eUp to ±10 A \/ phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003e\u003cstrong\u003eAC Phase Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003eUp to 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003e\u003cstrong\u003eAC Line Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 9px; border-bottom: 1px solid #4b5563;\"\u003eUp to 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 9px;\"\u003e20-1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e🧰 Professional Use\u003c\/h2\u003e\n\u003cp\u003eThe KDJB-802Y is intended for use by appropriately trained electrical professionals. Protection relay testing involves hazardous electrical voltages and currents, and testing should be performed only according to applicable safety procedures and the manufacturer's operating instructions.\u003c\/p\u003e\n\u003cp\u003eThe equipment should not be treated as a general-purpose consumer electrical tester.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"padding: 22px; background: #fff7ed; border: 1px solid #fed7aa; border-radius: 12px; margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"color: #9a3412;\"\u003e⚠️ Specification Confirmation\u003c\/h2\u003e\n\u003cp\u003eSpecifications may vary according to final factory configuration. Before placing an order, confirm the exact output configuration, software functions, protection-test modules, accessories, calibration documentation and communication interfaces with the supplier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The KDJB-802Y relay protection tester should not be automatically represented as a CT\/PT analyzer unless the manufacturer specifically confirms CT\/PT analysis functions for the supplied configuration.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 30px;\"\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e🚚 \u003cstrong\u003eDomestic \u0026amp; International DDP Shipping Available\u003c\/strong\u003e\u003cbr\u003eWe offer door-to-door shipping solutions for B2B orders across India and internationally. DDP shipping, where available, can include customs clearance, applicable duties and taxes.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e🌎 \u003cstrong\u003eInternational customers:\u003c\/strong\u003e Message us with your \u003cstrong\u003equantity + city + country + postal\/ZIP code\u003c\/strong\u003e for a customized DDP shipping quotation.\u003c\/p\u003e\n\u003cp\u003e🇮🇳 \u003cstrong\u003eIndia customers:\u003c\/strong\u003e Door delivery available across India, subject to destination and shipment requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFinal shipping cost and DDP availability are confirmed before order processing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 style=\"color: #123b63;\"\u003e❓ Frequently Asked Questions\u003c\/h2\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is the KDJB-802Y?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe KDJB-802Y is a microcomputer-controlled secondary injection relay protection tester designed for electrical protection testing, commissioning and maintenance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is secondary injection testing?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSecondary injection testing applies controlled electrical current and voltage signals to protection-relay circuits to verify relay operation and protection-system response.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is the maximum AC current output?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe supplied specification indicates up to 40 A per phase and up to 120 A for three-phase parallel output.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is the frequency range?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe specified fundamental frequency range is 20-1000 Hz.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eCan this equipment be used in substations?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, it is positioned for relay protection testing, commissioning and maintenance applications associated with substations and electrical power systems.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eIs KDJB-802Y the same as a UTE 403 CT\/PT Analyzer?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThey should not be treated as the same product without manufacturer confirmation. KDJB-802Y is described as a relay protection tester, while UTE 403 CT\/PT Analyzer specifications concern CT\/PT analysis. Confirm the exact model before ordering.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; padding: 12px; border: 1px solid #ddd; border-radius: 8px;\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWho should operate this tester?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eQualified electrical engineers, protection technicians, commissioning personnel and appropriately trained laboratory operators should operate the equipment.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\u003csection style=\"padding: 30px; background: linear-gradient(135deg,#123b63,#2563eb); color: white; border-radius: 16px; text-align: center;\"\u003e\n\u003ch2 style=\"color: white;\"\u003e⚡ Need a Relay Protection Testing Solution?\u003c\/h2\u003e\n\u003cp style=\"font-size: 17px;\"\u003eContact Shanvis Store for current configuration, pricing, technical documentation, delivery options and India import support.\u003c\/p\u003e\n\u003cstrong\u003eKDJB-802Y Microcomputer Secondary Injection Relay Protection Tester\u003c\/strong\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Shanvis","offers":[{"title":"Default Title","offer_id":49569312145667,"sku":"KDJB-802Y-Microcomputer","price":549549.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/1447\/4755\/files\/Hdd149c6dcc2f40e58d378635b039021bl_8687e45c-7bc0-4d32-a177-34e9308cb221.jpg?v=1788589174","url":"https:\/\/www.shanvis.store\/products\/kdjb-802y-microcomputer-secondary-injection-relay-protection-tester","provider":"Shanvis","version":"1.0","type":"link"}